SICK

MOC3ZA-KAZ34A6

SKU: 6047864 Available to order
Price excluding VAT

Request a quote

    Safe motion monitoring and control | Standstill Monitor | MOC3ZA-KAZ34A6 | Supply voltage: 400 V | Voltage type: AC | Connection type: Spring terminals

    Safety integrity level
    SIL 3 (IEC 61508)
    Category
    Category 4 (EN ISO 13849)
    Performance level
    PL e (EN ISO 13849)
    PFHD(mean probability of a dangerous failure per hour)
    41 x 10-9(EN ISO 13849)
    TM(mission time)
    20 years (EN ISO 13849)
    Stop category
    1 (EN 60204-1)
    Drive safety functions
    Standstill
    Connection type
    Spring terminals, plug-in spring terminals
    Conductor cross section
    Single wire or fine wire (1x): 0.5 mm² ... 4 mm²Fine wire with ferrule according to EN 46288 (1x): 0.5 mm² ... 2.5 mm²
    Encoder interface
    Motor voltage measuring
    Supply voltage (A1/A2)
    400 V (320 V ... 440 V)
    Voltage type
    AC
    Maximum power consumption
    ≤ 10 VA
    Supply voltage of semiconductor application diagnostic outputs (A3/A4)
    24 V DC (11 V DC ... 30 V DC)
    Residual ripple
    10 %
    Measured/motor voltage
    ≤ 690 V AC
    For UL 508 applications only
    ≤ 600 V AC
    Voltage threshold Uan
    20 mV ... 400 mV, adjustable
    Standstill time ts
    0.2 s ... 6 s, adjustable
    Hysteresis (for detection of running motor)
    100 %
    Response time
    ≤ 100 ms
    Contact configuration (safety contacts)
    3 contacts NO, 1 contact NC
    Contact type
    Relay, positively guided
    Nominal switching voltage
    250 V AC
    Switching capacity in accordance with AC 15
    N/O: 3 A/230 V AC (EN 60947-5-1)N/C: 1 A/230 V AC (EN 60947-5-1)
    Switching capacity in accordance with DC 13
    1 A/24 V DC (EN 60947-5-1)
    Maximum switching frequency
    ≤ 1,200 /h
    Contact service life at 230 V / 5 A (AC) cos φ = 1
    ≥ 2 x 105switching operations
    Mechanical life
    ≥ 50 x 106switching operations
    Semiconductor outputs (ON, ERR)
    Electrically isolated supply via A3/A4Imax= 100 mA (short-circuit protected)ON for Release, ERR for Error
    Signal contacts 53/54 (normally open contact)
    3 A/250 V AC G. P.
    Dimensions (W x H x D)
    45 mm x 112 mm x 121 mm
    Weight
    400 g
    Mounting
    35 mm mounting rail according to EN 60715
    Terminals
    IP20 (EN 60529)
    Housing
    IP40 (EN 60529)
    Climate conditions according to
    25/060/04 (EN 60068-1)
    Vibration resistance
    10 Hz ... 55 Hz (EN 60068-2-6)
    Single shock
    30 g, 11 ms (EN 60068-2-27)
    EU declaration of conformity
    ACMA declaration of conformity
    cULus certificate
    EC-Type-Examination approval
    ECLASS 5.1.4
    27371904
    ECLASS 6.0
    27371819
    ECLASS 7.0
    27371819
    ECLASS 8.0
    27371819
    ECLASS 9.0
    27371819
    ECLASS 10.0
    27371819
    ECLASS 11.0
    27371819
    ECLASS 12.0
    27371819
    ECLASS 13.0
    27371819
    ECLASS 14.0
    27371819
    ECLASS 15.0
    27371819
    ETIM 6.0
    EC001449
    ETIM 7.0
    EC001449
    ETIM 8.0
    EC001449
    ETIM 9.0
    EC001449
    ETIM 10.0
    EC001449
    UNSPSC 091201.0
    41113704
    UNSPSC 100501.0
    41113704
    UNSPSC 111201.0
    41113704
    UNSPSC 120901.0
    41113704
    UNSPSC 131201.0
    41113704
    UNSPSC 140801.0
    41113704
    UNSPSC 151101.0
    41113704
    UNSPSC 160901.0
    41113704
    UNSPSC 171001.0
    41113704
    UNSPSC 180801.0
    41113704
    UNSPSC 190501.0
    41113704
    UNSPSC 200601.0
    41113704
    UNSPSC 210901.0
    41113704
    UNSPSC 220601.0
    41113704
    UNSPSC 230701.0
    41113704
    UNSPSC 240301.0
    41113704
    UNSPSC 250901.0
    41113704
    UNSPSC 260801.0
    41113704
    Download Datasheet

    Manuals, CAD models, certificates and other materials are available on the manufacturer's website:

    Open product page on manufacturer's website