Linear encoders | DAX | DAXTAN-0400RA1F0300W01 | Design: DAX Threaded | Communication interface: Analog / Current | Current output: 4 mA ... 20 mA | Connection type: Male connector, M12, 8-pin | Measurement range: 0 mm ... 400 mm | Supply voltage: 24 V DC (± 20%) | Sequence of signals: Signal 1: rising, signal 2: falling | Unusable range (zero zone/damping zone): 50 mm / 63 mm | Magnet type: Ring magnet | Thread offset: With thread offset | Thread shape: M18 x 1.5
MTTFD(mean time to dangerous failure)
123 years1)
Linearity
≤ 0.02% F.S. (Minimum 60 µm)1)2)
Repeatability
≤ ± 20 µm
Measured values
Positioning
Measuring range
0 mm ... 400 mm
Null zone
50 mm
Damping zone
63 mm
Magnet shape
Ring magnet
Configured for number of magnets
1 piece
Magnet travel speed
Any
Measuring frequency (internal)
< 2 ms
Communication interface
Analog
Communication Interface detail
Current
Output signal
4 mA ... 20 mA
Number of signals
Two output signals (one output signal + an inverted second output signal)
Sequence of signals
Signal 1: rising, signal 2: falling
Load resistance
100 Ω ... 500 Ω
Connection type
Male connector, M12, 8-pin
Pinouts
1=Output signal ground (0 V PIN 3); 2=Output signal ground (0 V PIN 5); 3=Signal 2; 4=n.c.; 5=Signal 1; 6=Power ground; 7=+24 V DC; 8=n.c.
Male connector coding
A-coded
Supply voltage
24 V DC (± 20%)
Current consumption
50…100 mA
Reverse polarity protection
Up to −30 V DC
Residual ripple
≤ 0.28 Vpp
Dielectric strength
500 V DC, 0 V against housing
Over voltage protection
≤ 36 V DC
Mechanical design
DAX Threaded
Thread shape
M18 x 1.5
Thread offset
With thread offset
Pressure pipe
Stainless steel 1.4404 (AISI 316L)
Housing
Aluminum (anodised), zinc, stainless steel, brass
Flange
Stainless steel 1.4305 (AISI 303)
EMC
According to EN 61000-6-2 and EN 61000-6-4
Enclosure rating
IP65 / IP671)
Operating temperature range
–40 °C ... +85 °C
Storage temperature range
–40 °C ... +65 °C2)
Permissible relative humidity
90 % (Condensation not permitted)
Resistance to shocks
100 g, 6 ms (IEC 60068-2-27)
Resistance to vibration
15 g / 10…2,000 Hz according to IEC 60068-2-6
Nominal operating pressure (PN)
350 bar
Max. overload pressure during operation (PNx 1.2)
420 bar
Max. test pressure in cylinder (PNx 1.5)
530 bar
EU declaration of conformity
✔
UK declaration of conformity
✔
ACMA declaration of conformity
✔
Moroccan declaration of conformity
✔
China RoHS
✔
cULus certificate
✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)
✔
ECLASS 5.0
27270705
ECLASS 5.1.4
27270705
ECLASS 6.0
27270705
ECLASS 6.2
27270705
ECLASS 7.0
27270705
ECLASS 8.0
27270705
ECLASS 8.1
27270705
ECLASS 9.0
27270705
ECLASS 10.0
27270705
ECLASS 11.0
27270705
ECLASS 12.0
27274304
ETIM 5.0
EC002544
ETIM 6.0
EC002544
ETIM 7.0
EC002544
ETIM 8.0
EC002544
UNSPSC 16.0901
41111613
Download Datasheet
Manuals, CAD models, certificates and other materials are available on the manufacturer's website:
Open product page on manufacturer's website